BNNMF - CARBON DIOXIDE

Product Identification

Product ID:CARBON DIOXIDE
MSDS Date:04/01/1989
FSC:6830
NIIN:00N017627
MSDS Number: BNNMF

Responsible Party
UNION CARBIDE CORP LINDE DIV
39 OLD RIDGEBURY RD
DANBURY, CT 06817-0001
US

Emergency Phone: 800-822-4357

Info Phone: 203-794-2000

Cage: 36346

Contractor
UNION CARBIDE CORP LINDE DIV
DANBURY, CT 06817-0001 US

Telephone: 800-822-4357; 304-744-3487

Cage: 36346

Ingredients

EVAL OF THE END PROD. REMEMBER, GASES & LIQ HAVE

RTECS: 9999999ZZ


TO READ & UNDERSTAND ALL LABELS & OTHER INSTRUCTIONS

RTECS: 9999999ZZ


PRESSURIZED SYSTEM. IF THERE IS A LEAK, CLOSE

RTECS: 9999999ZZ


THEN REPAIR LEAK.STORE IN WELL VENTILATED, COOL DARK

RTECS: 9999999ZZ


GAS CYLINDERS, OBTAIN A COPY OF PAMPHLET P-1, "SAFE

RTECS: 9999999ZZ


FOR HIGHER CONCENTRATIONS USE ONLY NIOSH/MSHA

RTECS: 9999999ZZ


FEMALE RATS EXPSD FOR A SINGLE 24 HR INTERVAL TO

RTECS: 9999999ZZ


DESIGN & REPORTING FLAWS, THE RESULTS MUST STILL BE

RTECS: 9999999ZZ


CONFIRM OR REFUTE THE EFFECTS REPORTED. THE

RTECS: 9999999ZZ


830 PSIG @ 21C.

RTECS: 9999999ZZ


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 100%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


ANTIDOTE. TREATMENT OF OVEREXP SHOULD BE

RTECS: 9999999ZZ


WHEN TWO/MORE

RTECS: 9999999ZZ


MAY COMBINE TO CREATE ADDTNL, UNEXPECTED HAZARDS.

RTECS: 9999999ZZ


YOU PRODUCE THE MIXT. CONSULT AN INDUSTRIAL

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGEST:A HIGHLY UNLIKELY ROUTE
OF EXPOS. FROSTBITE OF LIPS & MOUTH MAY RESULT FROM CONT W/LIQ.
SKIN ABSORP:NO EVIDENCE OF ADVERSE EFTS FROM AVAIL INFO.
INHAL:ASPHY. MODERATE CONC MAY CAUSE HDCH , DROWS, DIZZ, STINGING
OF NOSE & THROAT, EXCITATION, RAPID BRTHG, EXCESS SALIVATION, VOMIT
& UNCON. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: LACK OF OXYGEN CAN CAUSE DEATH.
SKIN:NO HARMFUL EFT EXPECTED FROM VAPOR. LIQ MAY CAUSE FROSTBITE.
EYE:VAPOR MAY CAUSE A STINGING SENSATION; LIQUID MAY CAUSE
FROSTBITE. CHRONIC: NO EVIDENCE O F ADVERSE EFFECTS FROM AVAILABLE
INFORMATION. OTHER EFTS OF OVEREXP: DAMAGE TO RETINAL GANGLION
CELLS & CNS (SUPP DATA)
Medical Cond Aggravated by Exposure:A KNOWLEDGE OF THE AVAILABLE
TOXICOLOGY INFORMATION AND OF THE PHYSICAL AND CHEMICAL PROPERTIES
OF THE MATERIAL SUGGEST THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE
EXISTING MEDICAL CONDITIONS.

First Aid

First Aid:INGEST:CALL MD IMMED . SKIN:IMMED WARM FROSTBITE AREA W/WARM
WATER (NOT TO EXCEED 105F). IN CASE OF MASSIVE EXPOS, REMOVE CLTHG
WHILE SHOWERING W/WARM WATER. CALL MD. INHAL:REMOVE TO FRESH AIR.
GIVE ARTF RESP IF NOT BRTHG. GIVE OXYGEN IF BRTHG DFCLT. CALL MD.
EYE:IMMED FLUSH THORO W/WATER FOR AT LEAST 15 MIN. CALL MD, PREF AN
OPTHALMOLOGIST, IMMED. NOTE TO MD:THERE IS NOT SPECIFIC (ING 2)

Fire Fighting

Extinguishing Media:CO*2 CANNOT CATCH FIRE. USE MEDIA APPROPRIATE FOR
SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
.EVAC ALL PERS FROM DANGER AREA.IMMED DELUGE CNTNRS W/WATER SPRAY
FROM MAXIMUM DISTANCE UNTIL (SUPP DATA)
Unusual Fire/Explosion Hazard:GAS CANNOT CATCH FIRE.CNTNR MAY RUPTURE
DUE TO HEAT OF FIRE.NO PART OF CNTNR SHOULD BE SUBJECTED TO A TEMP
HIGHER THAN 52C (APPROX 125F).MOST CNTNRS(SUPP DATA)

Accidental Release

Spill Release Procedures:EVAC ALL PERS FROM DANGER AREA.USE NIOSH/MSHA
APPRVD SCBA WHERE NEEDED.SHUT OFF LEAK IF W/O RISK.VENT AREA OF
LEAK/MOVE LEAKING CNTNR TO WELL-VENT AREA.TEST AREA, ESPECIALLY
CONFINED AREAS,FOR SUFF OX YGEN CONTENT PRIOR TO PERMIT RE-ENTRY OF
PERS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HIGH PRESS LIQUIFIED GAS. USE PIPING &
EQUIP ADEQ DESIGNED TO WITHSTAND PRESS TO BE ENCOUNTERED. CAN CAUSE
RAPID SUFFOCATION DUE TO OXYGEN DEFICIENCY.
Other Precautions:STORE & USE W/ADEQ VENT. CLOSE VALVE WHEN NOT IN USE
& WHEN EMPTY. CO*2, BEING HVR/AIR, TENDS TO ACCUM NEAR FLOOR OF AN
ENCLSD SPACE DISPLACING AIR UPWARD & CREATES AN OXYGEN-DEFICIENT
ATMOSPHERE. VEN T SPACE BEFORE ENTRY. VERIFY (ING 3)

Exposure Controls

Respiratory Protection:SELECT IN ACCORDANCE WITH OSHA 29 CFR 1910.134 &
ANSI Z88.2. FOR CONC UP TO 10 TIMES THE APPLICABLE EXPOS LIMIT ANY
NIOSH/MSHA APPRVD SUPPLIED AIR REP IS REC. UP TO 50 TIMES A
NIOSH/MSHA APPRVD RESP W /FULL FACEPIECE/SCBA IS REC. (ING 11)
Ventilation:LOCAL EXHAUST: PREFERRED. MECHANICAL (GENERAL): ACCEPTABLE.
Protective Gloves:INSULATED NEOPRENE.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:METATARSAL SHOES FOR CYLINDER HANDLING.
SELECT I/A/W OSHA 29 CFR 1910.132 AND 1910.133.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:COOL, THEN MOVE CNTNRS AWAY FROM FIRE AREA IF WITHOUT
RISK. EXPLO HAZ:ARE PROVIDED WITH A PRESS RELIEF DEVICE DESIGNED TO
VENT CONTENTS WHEN THEY ARE EXPSD TO ELEV TEMPS. EFTS OF OVERE
XP:MAY OCCUR. ONE PUBLISHED STUDY HAS RPTD AN INCREASED INCIDENCE
OF CARDIAC MALFORMATIONS IN OFFSPRING OF (ING 12)

Chemical Properties

Boiling Pt:B.P. Text:-109F,-79C
Vapor Pres:ING 15
Vapor Density:1.522@21C
Evaporation Rate & Reference:HIGH (BUTYL ACETATE = 1)
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS GAS AT NORMAL TEMPERATURE AND PRESSURE;
ODORLESS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI METALS, ALKALINE EARTH METALS, METAL ACETYLIDES, CHROMIUM,
TITANIUM ABOVE 550C, URANIUM ABOVE 750C.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:IN THE PRESENCE OF AN ELECTRICAL
DISCHARGE, CO*2 IS DECOMPOSED TO FORM CO AND OXYGEN.

Disposal

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE OUTDOORS. DISCARD
ANY PRODUCT, RESIDUE, DISPOSABLE CONTAINER OR LINER IN AN
ENVIRONMENTALLY ACCEPTABLE MANNER, IN FULL COMPLIANCE WITH FEDERAL,
STATE AND LOCAL REGULATIO NS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.